What range of pressure within the endotracheal tube cuff does the nurse maintain to prevent both injury and aspiration?
Show
Tracheostomy Tube Cuff ManagementAn adult individual receiving a tracheostomy tube will typically have a cuffed tracheostomy tube initially placed in order to reduce or eliminate gas leakage through the upper airway to provide more effective ventilation if the individual is on mechanical ventilation. Managing the cuff of the tracheostomy tube is important in preventing the effects of over-inflating or under-inflating the cuff. High-volume low-pressure cuffs may minimize trauma to the tracheal wall. Too high of cuff pressure can lead to damage to the tracheal wall. Tracheal capillary pressure lies between 20-30mmHG. An impairment of blood flow can occur between pressure ranges of 22-37 mmHG. Such high pressures prevent the delivery of oxygen to the small capillaries supplying the tracheal mucosa, resulting in ischaemia and necrosis. Therefore, a maximum pressure of 22mmHG is recommended. Complications of cuff over-inflation include: Tracheal stenosis, tracheomalacia, tracheo-esophageal fistula, and tracheo-innominate artery fistula. In addition to increased possibility of airway injury, higher cuff pressures also have a deleterious effect on swallowing. The swallowing reflex was progressively more difficult to elicit with increasing cuff pressure and when activated, the resulting motor swallowing activity and efficiency at elevating the larynx were depressed (Amethieu, R et al, 2012). Too low cuff pressure can result in ineffective positive pressure ventilation. Also, although the cuff does not prevent aspiration, the cuff may reduce the amount and speed at which aspirated material enters the airway. Cuff Pressure MeasurementTracheostomy tube cuff pressure should be monitored routinely and adjusted as necessary (Mitchell, R. et al, 2013). Check the cuff pressure after re-inflating the cuff and if there are any concerns for a leak. Cuff pressure should be maintained between 15-30 cm H2O (up to 22 mm Hg) . A pressure manometer is a hand hand held device used to measure tracheostomy tube cuff pressures. Cuff pressure measurement (CPM), performed with a manometer during the inspiratory phase, provides objective measurement of intracuff pressure that does not involve cuff deflation. Procedure for Checking Cuff Pressure with Pressure Manometer
Document the cuff pressures and the amount of air placed in the pilot balloon. Minimal Occlusion Volume TechniqueSince the minimal occlusion volume (MOV) technique utilizes cuff deflation, suction the patient before beginning and possibly during cuff deflation as needed. MOV is performed by deflating the cuff, then slowly re-injecting air (or sterile water depending on the type of tube) with a luer lock syringe while auscultating near the tracheostomy tube. Air is injected into the pilot line until there is no longer “a leak” or air going past the cuff. This means the airway is sealed. Minimal Leak TechniqueThe minimal leak technique is performed similarly to the minimal occlusion by first suctioning and slowly deflating the cuff of the tracheostomy tube. Re-inflate the cuff until no leak is heard with a stethoscope placed near the tracheostomy tube. Air is then slowly removed (typically about 1/2-1cc) from the cuff with auscultation until a minimal leak is heard at the end of inspiration. Other Cuff Management TechniquesPilot balloon palpation involves subjectively estimating cuff inflation by squeezing the external pilot balloon. This technique is not recommended. Placing a fixed amount of air (ie. 10cc) inside all pilot balloons is also not recommended. The amount of air that fills the pilot balloon is dependent on the size of the tracheostomy tube and diameter of the individual’s airway. These techniques can easily result in cuff over or under-inflation. A study by Rahmad, R et al (2017) compared fixed volume to pilot balloon palpation and compared them to cuff pressure manometry. In the fixed volume group 10cc of volume was provided to the endotracheal pilot balloon and resulted in 42 patients (43.3%) with normal cuff pressure, 9 patients (9.3%) had lower and 46 patients (47.4%) had higher cuff pressure than the normal range. In the pilot balloon palpation group, all patients had higher cuff pressure than the normal range. In fixed volume, the lowest and the highest pressures were respectively 15 cm and 100 cm of water. But in pilot balloon palpation group, they were respectively 70 cm and 160 cm of water. These ranges are significantly higher than normal and cuff pressure monitoring was recommended by the authors. Sources of Cuff LeaksA leak around the cuff is assessed by auscultation over the suprasternal notch or the lateral neck. A cuff leak can result in inadequate ventilation, which can be life threatening if not dealt with in a timely manner. Cuff leaks can have varying sources including:
Cuff DeflationThe indication for inflating the cuff of the tracheostomy tube is to effectively provide positive pressure ventilation. Some individuals can be ventilated with the cuff deflated or cuffless tracheostomy tubes. Again, although the cuff does not prevent aspiration, it may reduce the amount and speed of aspirated material from entering the airway. Some individuals are unable to tolerate cuff deflation due to an inability to clear secretions. Subglottic suctioning, slow cuff deflation and mechanical insuflation-exsufflation may aide in the ability to tolerate cuff deflation. Once the individual is using a trach collar, a deflated cuff can speed up the weaning process. In a randomized controlled study, Hernandez, R. et al (2013) found that individuals with a deflated cuff weaned faster than those with an inflated cuff. The deflated cuff condition also had less respiratory infections. SummaryCuff management is a standard of care for patients with tracheostomy. Use of a cuff manometer to measure cuff pressures is recommended to prevent complications of cuff under or overinflation. Related Webinars
Resources:Rahmani F, Soleimanpour H, Zeynali A, et al. Comparison of tracheal tube cuff pressure with two techniques: fixed volume versus pilot balloon palpation. J Cardiovasc Thorac Res. 2017;9(4):196–199. doi:10.15171/jcvtr.2017.34 Which range of water pressure within the endotracheal tube cuff is believed to prevent both injury and aspiration?Which of the following ranges of water pressure identifies the amount of pressure within the endotracheal tube cuff that is believed to prevent both injury and aspiration? Usually the pressure is maintained at less than 25 cm water pressure to prevent injury and at more than 20 cm water pressure to prevent aspiration.
Does endotracheal cuff pressure prevent aspiration?Background. A critical function of the endotracheal tube cuff is to seal the airway, thus preventing aspiration of pharyngeal contents into the trachea and to ensure that there are no leaks past the cuff during positive pressure ventilation.
Does a cuffed endotracheal tube prevent aspiration?Endotracheal intubation with a cuffed tube is thought to prevent pulmonary aspiration, but studies have shown that small amounts of liquids can bypass the cuff by following the longitudinal folds in the cuff wall.
How does endotracheal tube prevent aspiration?The inflated ETT cuff seals the airway, allowing ventilation to only occur though the tube lumen, and prevents movement of air and fluid around the ETT [4].
|